Thermal shock | TSV-70L-A |
---|---|
Application test | Thermal Shock, Thermal Fatigue Test |
Equipment ability | -75℃ ~ 200℃(Trans 2min) |
Thermo-hygrostat | PDR-3KP |
---|---|
Application test | HHCO, HHC, Temperature and humidity Cycle |
Equipment ability | -30℃~110℃, 30~98%R.H |
Thermo-hygrostat | PDR-4KP |
---|---|
Application test | HHCO, HHC, Temperature and humidity Cycle |
Equipment ability | -30℃~110℃, 30~98%R.H |
hypsithermal age | TD500 |
---|---|
Application test | Intermittent operation duration, Continuous operating duration |
Equipment ability | room temperature~200℃ |
Thermo-hygrostat | EGNX12-6CAL |
---|---|
Application test | HHCO, HHC, Temperature and humidity Cycle Power Temp Cycle |
Equipment ability | -70℃~200℃, 10~95%R.H |
Ozone tester | SOZ-6300 |
---|---|
Application test | Ozone test |
Equipment ability | room temperature~150 ℃, Ozone : 0~2 ppm |
BenchTester | D21000001 |
---|---|
Application test | Regulator Operation Test |
Equipment ability | -40~150℃, heating /Cooling rate :3℃/min |
Accelerationtester | TPC-211 |
---|---|
Application test | AUTO CLAVE |
Equipment ability | Pressure:0.2~2 kg/㎠,(15 PSI), 75~100%R.H.125 ℃ |
Vibrator | TA250-S062 |
---|---|
Application test | Sine&Random Vibration |
Equipment ability | Acceleration~65G, Frequency:2~3500 ㎐ |
Mechanicalimpactor | SD-4.5HP |
---|---|
Application test | Mechanical Shock |
Equipment ability | Acceleration:MAX. 5000 G |
LOADDUMP | NSG-5000 |
---|---|
Application test | Surge, Electrical Stress |
Equipment ability | DC 600V MAX R:30 Ω Max, Pulse발생 |
Bipolar Power Supply | |
---|---|
Application test | Voltage intermittent Test Voltage interruption Test |
Equipment ability | Voltage : -20V ~ 20V CURRENT : -20A ~ 20A |
CurveTracer | 371A |
---|---|
Application test | dissection (chip & diode) |
Equipment ability | 30mW ~ 3kW |
Noise Measure System | |
---|---|
Application test | Noise Measure |
Equipment ability | Lower limit frequency:340 ㎐, Measurement frequency : Real Time analysis |
고저온Measure기 | XL-30,DX-41 |
---|---|
Application test | CAPACITOR Measurement of high and low temperature characteristics |
Equipment ability | Temperature : -55~150 ℃ |
Hot Air Reflow | |
---|---|
Application test | Hot Air Reflow Soldering |
Equipment ability | Temperature : room temperature ~ 300 Speed:5~60 cm/min |
Ripple generator | RG-2000 |
---|---|
Application test | Ripple test |
Equipment ability | DC 500 V MAX, Freq.:120㎐~100 ㎑ |
Solderabilitytester | MUST SYS.Ⅱ |
---|---|
Application test | Solderability test |
Equipment ability | Temperature:235~300 ℃, Deposition rate:1~20 mm/s |
Classification | Test Equipment | Major Specification | Q'ty | Applicable Test ITEM |
---|---|---|---|---|
CLIMATIC TEST |
Dry Oven (hypsithermal age ) |
Temperature Range: Room Temp . ~ 200 ℃ | 15 | High Temperature Test High Temp. Life Test |
Humidity Chamber (Thermo-hygrostat) |
Humidity Range : 30 ~ 98 % R.H Heat Up Rate : 45 min(-40 ~ 100 ℃) Cool Down Rate : 50 min(20 ~ -40 ℃) |
8 | Humidity & Humidity Cyclic Test Temperature Cyclic Test Power Temp Cycle |
|
Low Temperature Chamber |
Temperature Range : -70 ~ 100 ℃ Heat Up Rate : 30 min(20 ~ 100 ℃) Cool Down Rate : 60 min (20 ~ -70 ℃) |
2 | Dry Heat Test Low Temperature Test Low Temp Operation Test |
|
Pressure Cooker Tester |
Temperature Range : 105 ~ 143 ℃ Humidity Range : 75 ~ 100 % R.H Pressure Range : 0.2 ~2.0 kg/㎝ 2 |
2 | Acceleration Test | |
Thermal Shock Tester |
Temperature Range : -70 ~ 200 ℃ Trans Time : 2 min max |
1 | Thermal Shock Test Thermal Fatigue Test |
|
Ozone Tester |
Temperature Range : Room Temp ~ 150 ℃ Ozone : 0~2 ppm |
1 | Ozone test | |
Flammability Tester | Flammability Control : 12mm, 20mm, Time Control : 9999 s |
1 | Flammability Test | |
Bench Tester | Temperature Range : -40 ~ 150 ℃ heating /Cooling rate : 3 ℃ / min |
1 | Regulator Operation Test | |
Salt Fog Tester | Temperature Range : 20 ~ 40 ℃ Concentration of Brine : 5 %, 10 %, 15 % |
1 | Salt Spray Test | |
Vaccum Dry Oven | Troom ~ 60℃, Vaccum 0~760 torr |
1 | Decompression test |
Classification | Test Equipment | Major Specification | Q'ty | Applicable Test ITEM |
---|---|---|---|---|
MECHANICAL TEST | Vibrator | Max. Force : 600 LBS Peak Max. Acceleration : 65 G Frequency : 2 Hz ~ 3,500 Hz |
1 | Vibration Test(room temperature) |
Mechanical Shock Tester | Max. Acceleration : 5000 G | 1 | Shock Test |